Design consideration for a PV array installed on building walls

机译:建筑墙上安装了PV阵列的设计考虑因素

获取原文

摘要

This paper predicts relationship between array performance and surrounding ambient including installation conditions for PV array installed on building walls. A PV system assumed for calculation is a PV array installed on the north, south, east and west walls of a building which was constructed as a NEDO field test project. In the case of performance simulation for the actual PV system, calculated performance generally agrees with real measured data. Based on them, produced electrical energy is simulated as a function of ground albedo, array tilt angle and space between the PV array and the wall for installation. Effect of sub-array installation on different walls on DC power output is also estimated.
机译:本文预测阵列性能与周围环境之间的关系,包括安装在建筑物墙壁上的PV阵列的安装条件。假设用于计算的PV系统是安装在建筑物的北部,南,东部和西墙上的光伏阵列,该建筑物被构造为NEDO现场测试项目。在实际PV系统的性能模拟的情况下,计算性能通常同意实际测量数据。基于它们,产生的电能被模拟作为地面的函数,阵列倾斜角和PV阵列和墙壁之间的空间进行安装。还估计了子阵列安装在不同壁上的不同壁的影响。