Across the world the agreed phase out schedules for the HCFC R22 have led to the development of non-flammable zero ozone depletion potential (ODP) replacements. Most of these have included R32 as one of the blend components and require fullysynthetic lubricants such as ester based oils, but there is one non-flammable replacement that has been developed which does not utilise R32 and can be used with traditional lubricants in the majority of applications. This paper discusses the developmentof the blend comparing the performance characteristics under laboratory conditions. Several leak scenarios are investigated to ascertain the theoretical worst case scenario and considers the implications on flammability. Finally the oil transportproperties are investigated in order to assess the suitability of using the blend with traditional oils.
机译:全世界对HCFC R22的商定淘汰计划导致了不易燃零臭氧耗尽潜力(ODP)替代品的开发。其中大部分都包括R32作为混合组分之一,并且需要诸如酯基油的完全合成润滑剂,但是已经开发出一种不易燃的替代品,其不利用R32,并且可以与大多数的传统润滑剂一起使用应用程序。本文讨论了混合的发展比较了实验室条件下的性能特征。调查了几种泄漏情景以确定理论最糟糕的情况,并考虑对易燃性的影响。最后调查了石油运输代价化,以评估使用与传统油混合物的适用性。