摘要

This paper has investigated the use of a Rogowski transducer for measuring large current pulses. It has explained why passive L/r integration is generally unsuitable due to rings on the measured waveform. Passive CR integration with an appropriately terminated coil is possible for current pulses of duration up to typically 5 /spl mu/s but suffers from low sensitivity. Active plus CR integration yields the best results and can be used for current pulses of up to 50 ms duration without adverse droop effects. This method maybe used for pulses of much higher magnitude (e.g. 500 kA) than described in this paper, using the same coil dimensions. The only limitation is dI/dt which can result in large values of induced coil voltage, e. Typical coils produced by PEM are limited to 25 kA//spl mu/s although special coils rated at 100 kA//spl mu/s have been produced.
机译:本文研究了rogowski换能器测量大电流脉冲的使用。它已经解释了为什么由于测量波形上的环导致被动L / R积分通常不适合。与适当终止线圈的被动CR集成对于通常为5 / SPL MU / S的电流持续时间,但遭受低灵敏度。 Active Plus CR集成产生了最佳结果,可用于最多50毫米持续时间的电流脉冲,而无需不利下垂效果。这种方法可以使用比本文中的更高幅度(例如500ka)的脉冲,使用相同的线圈尺寸。唯一的限制是DI / DT,可以导致诱导线圈电压的大值,例如。 PEM产生的典型线圈限于25k // SPL MU / s,尽管已经产生了在100ka // SPL MU / S处的特殊线圈。