Multipoint calibration of electrodes for determination of pH-values is described using ordinary least square techniques. Calculation of the electrode parameters as measured slope k', electromotive efficency ss and zeropotentical-point pH_(0) are given for centre/slope- and intercept/slope-definition of the calibration line. The estimated standard deviations of these electrode parameters sdv (k'), sdv (ss), sdv (pH_(0)) are given. The uncertainity of measurement u_(r) and of the measured pH-value U(pH) is calculated by means of error propagation. Symbols and abbreviations text formulas standard pH values pH(S) x_(c) measured pH values pH(M) y_(c) EMF of standard buffer solution E(S) y_(c) EMF of unknown solution E(X) y_(a) measured pH value of unknown solution pH(m) y_(a) calculated pH of unknown solution pH(X) x_(a) number of buffer solutions N n_(c) Nernst slope k measured slope k' electromotive efficiency ss uncertainity of measurment u_(r) uncertainity of labeled pH value U(pH)
机译:使用普通的最小二乘技术描述用于确定pH值的电极的多点校准。作为测量斜率K'的电极参数的计算,电动效率SS和Zeropotical点PH_(0)被给出校准线的中心/斜率和截止/斜率定义。给出了这些电极参数SDV(K'),SDV(SS),SDV(PH_(0))的估计标准偏差。通过误差传播计算测量u_(r)和测量的pH值U(pH)的不确定性。符号和缩写文本公式标准pH值pH值(s)x_(c)测量pH值pH值pH值(m)y_(c)y_(c)emf的标准缓冲溶液e(s)y_(c)y_(c)emf未知解决方案e(x)y_( a)测量的pH值未知溶液pH(m)y_(a)计算的pH值未知溶液pH(x)x_(a)缓冲液的次数n n_(c)内部斜率k测量斜率K'电动效率Ss underthity测量U_(R)标记pH值U(pH)的不确定性