首页> 外文会议>Conference of epidemiology, prevention, and treatment >Visual evoked potential measurement of contrast sensitivity in a case of retinal laser injury reveals visual function loss despite normal acuity
【24h】

Visual evoked potential measurement of contrast sensitivity in a case of retinal laser injury reveals visual function loss despite normal acuity

机译:尽管正常的敏锐度,视网膜激光损伤的情况下,视觉诱发潜在的对比度敏感性测量揭示了视觉功能损失

获取原文

摘要

Although visual function following retinal laser injuries has traditionally been assessed by measuring visual acuity, this measure only indicates the highest spatial frequency resolvable under high-contrast viewing conditions. Another visual psychophysical parameter is contrast sensitivity (CS), which measures the minimum contrast required for detection of targets over a range of spatial frequencies, and may evaluate visual mechanisms that do not directly subserve acuity. We used the visual evoked potential (VEP) to measure CS in a population of normal subjects and in patients with ophthalmic conditions affecting retinal function, including one patient with a laser injury in the macula. In this patient, the acuity had recovered from $LSEQ 20/100 initially after the exposure, to 20/16 at the time of this investigation (5 months post exposure). Visual stimuli consisted of counterphasing, sinusoidally-modulated luminance gratings presented at various spatial frequencies. VEPs were recorded with a gold cup electrode on the occipital scalp, and were demodulated in real time by a lock-in amplifier referenced to the stimulus counterphase frequency. As each grating was presented, its contrast was swept logarithmically from 0% to 50% over a 12-sec epoch. The CS was scored as the reciprocal of the lowest contrast within the sweep which elicited a response synchronized to the counterphase frequency. We found a CS deficit that appeared for a 3$DGR test field but not for larger test fields. These data indicated that contrast sensitivity measurements may reveal alterations in visual neural processing mechanisms not detected with standard clinical tests of acuity.
机译:虽然通过测量视力传统上评估了视网膜激光损伤后的视觉功能,但该措施仅表示在高对比度观察条件下可分辨的最高空间频率。另一个视觉心理物理参数是对比度灵敏度(CS),其测量在一系列空间频率上检测目标所需的最小对比度,并且可以评估不直接使用敏锐度的视觉机制。我们使用视觉诱发的电位(VEP)测量正常受试者群体中的CS,并在影响视网膜功能的眼科病症患者中,包括在黄斑中的激光损伤的一名患者。在这名患者中,敏锐于曝光后的$ LSEQ 20/100从$ LSEQ 20/100恢复到20/16,在这项调查时(暴露后5个月)。视觉刺激包括在各种空间频率上呈现的正弦调制亮度光栅。 veps用枕骨头皮上的金杯电极记录,并通过引用刺激逆时频率的锁定放大器实时解调。当呈现每个光栅时,其对比度将以12-SEC时期的0%〜50%扫描。 CS被评分为扫描内的最低对比度的倒数,其引发与逆住频率同步的响应。我们发现了一个CS缺陷,它出现了3美元的DGR测试字段,但不是更大的测试字段。这些数据表明,对比度敏感性测量可以揭示未检测到的视觉神经加工机制的改变,其敏锐标准临床试验。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号