Code Case N-659 Revision 0 was approved in 2002 to allow ultrasonic examination (UT) an alternative to radiography (RT) for nuclear power plant components and transport containers under Section III of the ASME Code. The Nuclear Regulatory Commission has not approved N-659 and its subsequent revisions (currently N-659-2) for general use, but they have been used on a case-by-case basis mainly where logistic problems or component configuration have prevented the use of radiography. Like the parallel Code Case 2235 for non-nuclear applications under Section I and Section VIII, Code Case N-659 requires automated, computerized ultrasonic systems and capability demonstration on a flawed sample as a prerequisite for using UT in lieu of RT. Automated ultrasonic examination can be significantly more expensive than radiography, so a cost-benefit evaluation is a key factor in the decision to use the Code Case. In addition, the flaw sample set has recently become an issue and a topic of negotiation with the NRC for application of the Case. A flaw sample set for a recent radioactive material transport cask fabrication project was successfully negotiated with the NRC. The Code Case N-659 approach has been used effectively to overcome barriers to Code required radiography. Examples are examination of welds in an assembled heat exchanger and in a radioactive material transport cask assembly where internal shielding prevented radiography of the weld. Future development of Code Case N-659 will address sample set considerations and application-specific Code Cases, such as for storage and transport containers, will be developed where NRC concerns have been fully addressed and regulatory approval can be obtained on a generic basis.
机译:代码案例N-659修订版0是2002年批准的,允许超声波检查(UT)替代用于核电站组件和ASME代码第三节下的运输容器的替代。核制委员会尚未批准N-659及其随后的修订(目前为N-659-2),但它们主要用于逐个案例基础,主要是在逻辑问题或组件配置阻止使用情况下射线照相。与在第i节和第VIII部分下的非核应用的并行代码案例2235,代码案例N-659需要在缺陷的样品上自动化,计算机化的超声波系统和能力演示作为使用UT代替RT的先决条件。自动超声检查比射线照相昂贵,因此成本效益评估是使用代码案例的决定中的关键因素。此外,缺陷样本集最近已成为一个问题和与NRC进行谈判的主题,以便申请案件。为最近的放射性物质运输桶制造项目设定了一个缺陷样本,并用NRC成功地协商。代码案例N-659方法已经有效地用于克服所需射线照相的代码的障碍。实施例是在组装的热交换器中和放射性物质运输桶组件中的焊缝检查,其中内部屏蔽防止焊接的射线照相。未来的代码案例N-659的发展将解决样本设置注意事项和特定于应用的代码案例,例如用于存储和运输容器,将制定NRC疑虑已完全解决,并且可以在通用基础上获得监管批准。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号