摘要

Radiographic Test (RT) has been widely used in industries to detect inner defects of welded structures or any other significant components. Especially in the nuclear industry, film radiography is the dominant and standardized procedure in performing radiographic testing. Lately emphasis is on digital radiography. One of the most serious concerns for digitization is the lack of image resolution standardizing device like resolution gauge which would determine imaging parameters such as modular transfer function (MTF). This paper proposes line pair type image quality indicator (IQI) corresponding to the current IQIs for both hole and wire type. The advantage of this IQI is to enable easier calibration of testing conditions and quantification of digital RT image quality with required MTF that should be clearly defined in the examination procedures. Furthermore, to acquire "resolution-ensured" digital image of existing RT films, we developed line pair type standardization film. Prototypes of line pair type IQI and line pair type standardization film are currently in the validation study and trial implementing process. These results are also reported in this paper.
机译:射线照相试验(RT)已广泛用于行业,以检测焊接结构的内部缺陷或任何其他有效部件。特别是在核工业中,薄膜射线照相是在进行射线照相测试时的主导和标准化程序。最近强调数字射线照相。数字化最严重的疑虑之一是缺乏像分辨率规范的图像分辨率标准化装置,其将确定成像参数,例如模块化传递函数(MTF)。本文提出了对应于孔和线型的当前IQIS对应的线对型图像质量指示器(IQI)。该IQI的优点是为了使测试条件的更容易校准,数字RT图像质量的量化与所需的MTF应在检查程序中清楚地定义。此外,要获得现有RT膜的“分辨率”数字图像,我们开发了线对类型标准化膜。线对类型IQI和线对类型标准化胶片的原型目前在验证研究和试验过程中。本文还报道了这些结果。