首页> 外文会议>ASME International Mechanical Engineering Congress and Exposition >INSTRUMENTATION FOR PERFORMANCE MEASUREMENTS OF HEAT PUMPS WITH COMMERCIAL DESUPERHEATERS
【24h】

INSTRUMENTATION FOR PERFORMANCE MEASUREMENTS OF HEAT PUMPS WITH COMMERCIAL DESUPERHEATERS

机译:商业脱水器的热泵性能测量仪器仪表

获取原文

摘要

The current project is an extension of the original "ETME 475-Mechanical Systems Design" course project with a new National Instruments data acquisition board, a newly developed LabVIEW data acquisition program, and with a more realistic heat transfer loop. The study covers performance of our heat pump operating in A/C mode as well as in heating mode with a commercial desuperheater (a cross-flow heat exchanger). For this project, the experimental set up consisted of a desuperheater spliced into Trane XL1000, 2-ton, 10-SEER heat pump and a heat transfer loop with a 72-liter hot water storage tank. The instrumentation consisted of seven copper-constantan thermocouples and a LabVIEW-based computer data acquisition system. The thermocouples were used to measure refrigerant, water, indoor air and ambient air temperatures. The LabVIEW based computer data acquisition system was used to record temperatures. Indoor airflow rate was previously measured using Alnor LoFlo balometer.
机译:目前的项目是原始的“ETME 475机械系统设计”课程项目的延伸,具有新的国家仪器数据采集板,新开发的LabVIEW数据采集程序,以及更现实的传热环路。该研究涵盖了我们在A / C模式下操作的热泵以及具有商业脱水器(横流式热交换器)的加热模式的性能。对于该项目,实验设置由脱果换热器组成,拼接成三角XL1000,2吨,10-Seer热泵和带有72升热水储存罐的传热环。仪器包括七个铜常数热电偶和基于LabVIEW的计算机数据采集系统。热电偶用于测量制冷剂,水,室内空气和环境空气温度。基于LabView的计算机数据采集系统用于记录温度。以前使用Alnor Loflo Banlomomer测量室内气流速率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号