首页> 外文会议>Optical and imaging techniques in biomedicine >Quality control of instrumentation in videomicroscopy incidence on DNA analysis
【24h】

Quality control of instrumentation in videomicroscopy incidence on DNA analysis

机译:DNA分析仪器仪表中仪器的质量控制

获取原文

摘要

Recent advances in video microscopy in the field of cytopathology need to define in detail requirements for rigorous technical quality control of DNA analysis. This study deals with the influence of both quality and calibration of instrumentation on DNA content measurements. Quality control of instrumentation in stability, linearity, and shading estimations has been achieved for two SAMBA$+TM$/2005 (ALCATEL-TITN-Answare/France) image analysis systems by using prototype reference standard slide and Feulgen-stained rat liver imprints. The accuracy of the various conditions of work has been expressed as the CV of integrated optical density (IOD) and varied from 1.5% to 5.4%. These results demonstrate the dependence of the accuracy of measurements on the conditions for calibration of the instrument. Moreover, this work shows that each system can be characterized by its specific answer and all the systems don't really offer acceptable conditions for nuclear DNA content determination.
机译:缩细胞病变领域的视频显微镜最近的进展需要为DNA分析进行严格的技术质量控制的详细要求。本研究涉及质量和仪器质量和校准对DNA含量测量的影响。通过使用原型参考标准载玻片和Feulgen-Wath肝脏印记,为两个Samba $ + TM $ / 2005(Alcatel-TITN-Answare / France)图像分析系统已经实现了稳定性,线性度和阴影估计的仪器的质量控制。各种工作条件的准确性已表示为集成光密度(IOD)的CV,并从1.5%变化至5.4%。这些结果证明了测量精度对仪器校准条件的依赖性。此外,这项工作表明,每个系统都可以其特定的答案为特征,并且所有系统都没有真正为核DNA含量测定提供可接受的条件。