首页> 外文会议>Joint ASME/JSME Pressure Vessels and Piping Conference >Thermal Stratification of Surge Line in PWR Nuclear Power Plant
【24h】

Thermal Stratification of Surge Line in PWR Nuclear Power Plant

机译:PWR核电站电涌线的热分层

获取原文

摘要

Recent observations at operating plants and subsequent U.S.NRC requirements have identified flow stratification in surge lines as a phenomenon that must be considered in the design basis of surge lines. During YGN(Younggwang Nuclear) unit 3 pre-core hot functional testing, surge line pipe wall temperatures and pipe displacements were measured to determine the degree of surge line flow stratification. Test data from YGN Unit 3 indicate that stratified flow exists in the surge during heatup and cooldown. This paper presents the circumferential and axial temperature distributions and the pipe movements measured from surge line stratification testing performed during the YGN Unit 3 pre-core hot functional test.
机译:最近在运营植物和随后的U.S.NRC要求中的观察结果已经确定了喘振线的流程分层作为在喘振线的设计基础上必须考虑的现象。在YGN(Outyggwang核)单元3期间核心热功能测试,测量喘振管壁温度和管道位移,以确定喘振线流程分层的程度。来自YGN单元3的测试数据表明热量和冷却期间的浪涌存在分层流量。本文介绍了在YGN单元3预核热功能测试期间从喘振线分层测试测量的圆周和轴向温度分布和管道运动。