rd of the proof-test stress has been commonly quoted as the maximum allowable stress to ensure longevity of fibers. However, the basis of the rule are not appropriate for some installation practices and modern fibers. The Weibull parameter m for low-stress breaks was measured using a proof tester. The fatigue constant n was replaced with the parameter obtained from an abraded fiber. Using the new parameters and appropriate failure probabilities, engineering guidelines were derived for three representative lengths: 1000 km (long-haul cable), 1 m (fiber in a splice closure), and 1 cm (bent section of a pigtail fiber).
机译:证据测试应力的RD通常引用为确保纤维寿命的最大允许应力。但是,规则的基础不适合某些安装实践和现代纤维。使用校样测试仪测量用于低应力断裂的Weibull参数M.用从磨损纤维获得的参数替换疲劳常数N.使用新的参数和适当的失败概率,为三个代表长度推导出工程准则:1000公里(长途电缆),1米(拼接封闭纤维),1厘米(尾纤纤维的弯曲部分)。