In practice, there is no available general relationship between the measurable transferred energy into the insulation of a test object and the damaging energy inside the partial discharge (PD) afflicted void. One of the reasons is that there is no applicable general model from which such a relationship can be concluded. This paper sheds light on a new method for determining generally the required energy relationship based on a mathematical model for a modified extended equivalent circuit of a PD afflicted solid insulation. The relationship can be obtained from a simulated PD signal. For simplicity and clarity a solid insulation bulk with only one void which has one PD source is considered.
机译:实际上,可测量的转移能量与测试物体的绝缘体之间没有可用的一般关系,以及局部放电内部的损坏能量(PD)受到折磨的空隙。其中一个原因是,没有适用的一般模型,可以得出这样的关系。该纸张揭示了一种新方法,用于基于PD的改进的延伸等效电路的数学模型来确定所需的能量关系。可以从模拟PD信号获得关系。为简单和清楚起见,考虑只有一个空隙的固体绝缘体积被认为是具有一个PD源的一个空隙。