首页> 外文会议>Mediterranean Conference on Medical and Biological Engineering and Computing >Non-Invasive Intrauterine Pressure Estimation Based on Nonlinear Parameters Computed from the Electrohysterogram
【24h】

Non-Invasive Intrauterine Pressure Estimation Based on Nonlinear Parameters Computed from the Electrohysterogram

机译:基于电力阶段计算的非线性参数的非侵入性宫内压力估计

获取原文

摘要

Monitoring uterine contractions is essential during pregnancy and labor to obtain information on time-to-delivery and maternal and fetal wellbeing Intrauterine pressure (IUP) is considered the "gold standard" to monitor uterine activity, though it requires membrane rupture and is highly invasive. Considering that uterine mechanical activity is a direct consequence of uterine myo-electrical activity, IUP signal can be non-invasively estimated from abdominal electrohysterogram (EHG) recordings. Previous works have reported EHG-based IUP estimates with linear parameters as root-mean-square or Teager energy. Due to non-linear nature of biological processes, the aim of this study was to test the performance of different non-linear EHG parameters to estimate IUP signal. Simultaneous EHG and IUP recordings were conducted in 17 women during labour. Teager energy (TE), Sample entropy (SampEn), Spectral entropy (SpEn), Lempel-Ziv (LZ), and Poincare parameters: SD1, SD2, SDRR and SD1/SD2 were computed from the EHG. Different window lengths for computation and for a smoothing moving average filter were tested. Mono-variable linear regression models were used to obtain IUP estimates. The best results were obtained with TE and SD1, both computed and filtered with windows of 5 s and 20 s, respectively. In the latter case, the RMSerror was 12.25 ± 4.03 rnmHg, which points that non-linear EHG parameters can provide relevant information for non-invasive uterine activity monitoring.
机译:监控子宫收缩是怀孕和分娩期间必需,以获得按时到交付和母体和胎儿的福利宫内压力(IUP)被认为是“黄金标准”来监控子宫活动信息,但是它需要膜破裂并且是高度侵入性的。考虑到子宫机械活动是子宫肌肉的电活动的直接后果,IUP信号可以非侵入性地从腹部electrohysterogram(EHG)录音估计。以前的作品曾报道基于EHG-IUP估计与线性参数,根均方或Teager能量。由于生物过程的非线性性质,本研究的目的是测试不同的非线性EHG参数的性能来估计IUP信号。同时EHG和IUP录音中有17名妇女在分娩期间进行的。 Teager能量(TE),样品熵(SampEn),光谱熵(SPEN)的Lempel-谢夫(LZ),和Poincare参数:SD1,SD2,SDRR和SD1 / SD2是从EHG计算。用于计算和用于平滑移动平均滤波器不同窗长度进行测试。单变量线性回归模型来获得IUP估计。最好的结果是用TE和SD1获得,既计算并与分别为5秒和20秒,窗过滤。在后一种情况下,是RMSerror 12.25±4.03 rnmHg,这点,非线形参数EHG能提供非侵入式子宫活动监视相关信息。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号