摘要

An in situ method to determine the specific activity in concrete structures using a survey meter was established in this study for decommissioning accelerator rooms.This method is much simpler than the conventional sampling method that requires core boring.A survey meter(T-SP2,TAC Inc.,Japan)was customised and equipped with a small detector probe,whose size allowed the design of a light-weight Pb shield.For dose rate measurement,a Pb shield thickness of 4.5 cm was enough to shield ambient γ-rays,and its weight(16 kg)was low enough for the device to be carried by a human.A calibration curve was obtained to quickly and easily convert the net contact dose rate on concrete into the specific activity in a PET cyclotron room.The specific activity detection limit for this device was lower than the clearance limit of ~(152)Eu and ~(60)Co in activated materials.Therefore,this method can be used for separating non-activated concrete from activated concrete during decommissioning.A general correction factor for the slope of the calibration curve was also obtained for use at other accelerator facilities.
机译:在本研究中建立了在本研究中确定使用测量仪来确定混凝土结构中的具体活性的方法,用于退役加速室。该方法比需要核心钻孔的传统采样方法更简单。调查仪表(T-SP2,TAC公司,日本)定制并配备了一个小型探测器,其尺寸允许设计轻量级Pb屏蔽。对于剂量率测量,PB屏蔽厚度为4.5cm,足以屏蔽环境γ射线其重量(16 kg)足够低,对于人类携带的装置。获得校准曲线以快速且容易地将混凝土上的净接触剂量率转换为PET回旋室的特定活动。具体的活性检测该装置的限制低于激活材料中〜(152)欧盟和〜(60)Co的间隙限制。因此,该方法可用于在退役期间将非活化混凝土分离出从活性混凝土。一般的Correc还获得了校准曲线斜率的缩略因子,用于其他加速器设施。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号