Determination of harmonic responsibilities under the change of background harmonic impedance

机译:确定背景谐波阻抗变化下的谐波职责

获取原文

摘要

The change of background harmonic impedance caused by transformation of network structure or switching of loads reduces the accuracy of harmonic responsibilities determination. It is urgent to assess the harmonic responsibilities of customers in this case. This paper proposes a slope comparison method to segment the measurement data. The change time can be adaptively identified and the measurement data are segmented into several sections with different background harmonic impedances. Besides, the ranged major axis regression is introduced to determine the harmonic responsibility. The errors of independent variable are taken into account in the proposed regression method, so it will get higher accuracy in estimation. Furthermore, a total harmonic responsibility index is established to assess the total impact of customers. The simulations are conducted to verify the validity and correctness of the proposed method. Compared to current methods, the proposed method has higher effectiveness and accuracy.
机译:由网络结构转换或负载切换引起的背景谐波阻抗的变化降低了谐波职责的准确性。在这种情况下评估客户的谐波职责是迫切的。本文提出了一个斜率比较方法来分割测量数据。可以自适应地识别改变时间,并且测量数据被分段为具有不同背景谐波阻抗的几个部分。此外,引入了范围的主要轴回归以确定谐波责任。在拟议的回归方法中考虑了独立变量的错误,因此它将获得更高的估计准确性。此外,建立了总谐波责任指数,以评估客户的总影响。进行模拟以验证所提出的方法的有效性和正确性。与目前的方法相比,所提出的方法具有更高的有效性和准确性。