Usability characteristics assessment protocol applied to eTouch ultrasound user-defined workflow optimization tool

机译:可用性特性评估协议应用于ETouch超声用户定义的工作流优化工具

获取原文

摘要

The Ultrasound (US) examination time reduction is an increasing compelling request in sonographer's everyday life. The increased number of patients and the cost reduction are two opposite forces, which can lead the sonographer to work faster without caring about scanning posture. The numerous repeated actions performed can easily lead to Work-related Musculoskeletal Disorders (WRMSD). The analysis of those problems has driven to the definition and implementation of eTouch tool: user-defined Macros appositively created, automatically and sequentially saved and performed in real time by pressing a button. The present work investigates ergonomics and usability performances of a portable US system (MyLabAlpha, Esaote S.p.A., Italy) by using eTouch as well as the classical manual interface in two clinical applications (Abdominal and Vascular). performed by a skilled sonographer on a healthy subject. is. Upper-body kinematic and muscle activation of the sonographer's left arm were recorded through an optoelectronic system (SmartDx400, BTS Spa, Italy) and a multi-channel Wireless Superficial Electromyography (SEMG, Freemg300, BTS Spa, Italy). The number of keystrokes used during the manual procedure was more than 3 times higher than the one with eTouch. This difference implied a reduction of US execution time when using eTouch in comparison with manual use of about 30%. Results of the upper-body kinematic showed that the arm was extended for less time intervals when using eTouch, whereas during the manual procedure there was a greater activation of the deltoid, responsible for the elevation of the shoulder and thus the extension of the arm. SEMG analysis showed that eTouch allowed a significant reduction of muscular activation, especially for the anterior deltoideus. Our findings showed that eTouch is recommendable for decreasing WRMSD risk.
机译:超声(美国)考试时间减少是在超声波赫的日常生活中提高令人信服的要求。增加的患者数量和成本的成本是两个相反的力量,这可以引领超声波师在不关心扫描姿势的情况下更快地工作。进行的许多反复动作可以容易地导致与工作有关的肌肉骨骼疾病(WRMSD)。对这些问题的分析已经推动了Etouch工具的定义和实现:用户定义的宏同步,自动创建,通过按一个按钮自动和顺序地保存和实时执行。目前的工作通过使用ETOUCH以及两种临床应用中的经典手动界面(腹部和血管)来调查便携式美国系统(Mylabalpha,Esaote S.P.A.,Italy)的人体工程学和可用性。由一个熟练的声学家进行健康的主题。是。通过光电系统(SmartDX400,BTS SPA,意大利)和多通道无线浅表电拍(SEMG,Freemg300,BTS Spa,Italy)记录超声波左臂的上体运动和肌肉激活。手动过程中使用的击键数量比使用精触发高出3倍。当使用约30%的手动使用时,这种差异暗示使用ETOUCH时的执行时间。所述上身运动的结果表明,该臂用eTouch当延长的时间更短的时间间隔,而在手动操作过程中有一个更大的激活的三角肌的,负责肩的高度,从而该臂的延伸。 SEMG分析表明,ETouch允许显着降低肌肉激活,特别是对于前临时的肌肉激活。我们的研究结果表明,ETouch是推荐的,以降低WRMSD风险。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号