首页> 外文会议>International Cryogenics Engineering Conference >Test stand for determination of the heat flux to the cold elements of cryogenic systems in case of the vacuum vessel failure
【24h】

Test stand for determination of the heat flux to the cold elements of cryogenic systems in case of the vacuum vessel failure

机译:在真空容器失效的情况下,试验台用于测定低温系统的冷却元件的热量通量

获取原文

摘要

The design process of cryogenic equipment requires sizing of the safety accessories for all enclosures containing cryogenic gas or liquid. The size of the accessories depends on the heat load to the cryogen. Vacuum failure following the ventilation of the insulating vacuum with atmospheric air is often considered as a maximum credible incident. For such case the heat inputs to blank liquid nitrogen and to liquid helium vessels have been experimentally determined by other researchers. Nevertheless, for helium systems elements as an actively cooled thermal shield, with a MLI covered external side and bare internal side, experimental data does not exist. WUST has designed a test stand that allows the experimental determination of the heat flux to the helium vessel, nitrogen vessel and to the thermal shield in case of the accidental break of the vacuum. The paper describes the test stand design and test methodology.
机译:低温设备的设计过程需要含有含有低温气体或液体的所有外壳的安全配件。附件的尺寸取决于对低温原的热负荷。具有大气空气的绝缘真空通风后的真空破坏通常被认为是最大可信的事件。对于这种情况,对于空白液氮和液氦血管的热量通过其他研究人员实验确定。然而,对于氦系统元件作为主动冷却的热屏蔽,用外侧和裸侧的MLI覆盖,实验数据不存在。 WOUST设计了一种测试支架,其允许在真空中发生意外断裂的情况下,实验确定热量到氦气容器,氮容器和热屏蔽的热屏蔽。本文描述了测试台设计和测试方法。