首页> 外文会议>National Conference on Thermodynamics with International Participation >Research on the fire endurance of the silica sand membrane
【24h】

Research on the fire endurance of the silica sand membrane

机译:二氧化硅砂膜火灾耐力研究

获取原文

摘要

In this study,the fire endurance,density,low-temperature deflection,penetration and ring-ball method tests of the membrane produced throughout the mixing of Bitumen,IPP(isotactic polypropylene),LDPE(Low-density polyethylene)calcite and silica sand at varying proportions were performed and the test results were compared with the membrane used today.In our study,TS 120 EN 1427,TS 118 EN 1426,TS EN 13501-1,KG-TL-029 testing methods were used.The density of the silica material we have obtained was measured at 1.3782 g/cm~3,the endurance of the material was found out to be better,softening temperature was measured at 155°C,brittleness temperature at-7°C and the fire class was found out to be as E.
机译:在本研究中,在沥青,IPP(全同立构聚丙烯),LDPE(低密度聚乙烯)方解石和二氧化硅砂的整个混合过程中产生的膜的防火,密度,低温偏转,渗透和环球法试验进行了不同的比例,并将测试结果与今天使用的膜进行比较。在我们的研究中,使用TS 118 En 1426,TS EN 13501-1,KG-TL-029测试方法。密度我们获得的二氧化硅材料在1.3782g / cm〜3下测量,发现材料的耐久性是更好的,在155℃下测量软化温度,脆性温度在-7℃和火级别发现作为E.