Cryogenic air separation units are widely used in industry,which consume a large energy and need to produce a huge amount of need of nitrogen,oxygen and argon products with high purity.High purity distillation columns are critical unit operations in cryogenic air separation plants.In this paper the low pressure distillation column is investigated by using a steady state model.The first principles mathematic model of the column is firstly developed,and the pressure,temperature and static liquid nitrogen,oxygen and argon concentrations in the upper column are presented.The obtained results give important information on the variation of temperature,pressure,component concentrations and molar flows within the distillation column.The study highlighted the importance of considering air as ternary mixture.The separation process performance is significantly influenced by the location of side draw of argon and reflux ratio at the top of the column
机译:低温空气分离单元广泛用于工业中,消耗大量的能量,需要产生大量的氮,氧和氩产品,具有高纯度。高纯度蒸馏塔是低温空气分离厂的关键单位操作。本文通过使用稳态模型研究了低压蒸馏塔。首先开发了柱的第一个原理数学模型,并提出了上柱中的压力,温度和静态液氮,氧气和氩浓度。得到的结果提供了关于蒸馏塔内温度,压力,组分浓度和摩尔流动变化的重要信息。研究突出了考虑空气作为三元混合物的重要性。分离过程表现受氩的侧面绘制位置的显着影响和列顶部的回流比