This paper presents an alternative solution to conventional welded moment-resisting frame for circular hollow sections using blind bolts and double split tee connections. The easily installed blind bolts from one side offer great convenience for on site practice. Testing on T-stub components to circular column segments in tension shows that this type of connection has great strength and stiffness to be qualified for transferring moment within the composite structural frame. Cogged extensions to the blind bolts improve the tensile behaviour of the T-stub connection. The paper presents results from a detailed analytical study and comparison with experimental investigation. The strength hierarchy among the beam, column and joint for applications in various frame configurations is also discussed.
机译:本文介绍了用于使用盲螺栓和双链T恤连接的圆形中空部分的传统焊接力矩抵抗框架的替代解决方案。从一侧易于安装的盲螺栓为现场练习提供了极大的便利。在张力中对圆柱段的T-TUB组件测试表明,这种类型的连接具有良好的强度和刚度,符合在复合结构框架内的转移力矩。触摸螺栓的延伸延伸改善了T-Stub连接的拉伸行为。本文提出了一种详细的分析研究和与实验研究比较的结果。还讨论了在各种帧配置中梁,柱和关节之间的强度层次结构。