In the present study, three-dimensional numerical simulation of two shell-and-tube heat exchangers (STHXs) with conventional segmental baffles (STHXsSB) and continuous helical baffle (STHXsHB) is carried out and a comparative study is performed based on the simulation results. Both of the STHXs contain 37 tubes inside a 500 mm long and 200 mm diameter shell and mass flow rate of shell-side fluid is varied from 0.5 kg/s to 2 kg/s. At first, physical and mathematical models are developed and numerically simulated using finite element method (FEM). For the validation of the computational model, shell-side average nusselt number (Nu_s) is calculated from the simulation results and compared with the available experimental results. The comparative study shows that STHXsHB has 72-127% higher heat transfer coefficient per unit pressure drop compared to the conventional STHXsSB for the same shell-side mass flow rate. Moreover, STHXsHB has 59-63% lower shell-side pressure drop than STHXsSB.
机译:在本研究中,进行了具有常规节段挡板(STHXSSB)和连续螺旋挡板(STHXSHS)的两个壳管热交换器(STHXS)的三维数值模拟,并基于模拟结果进行比较研究。两个STHXS含有37个管在500mm长,直径200mm的壳体内,壳侧流体的质量流量从0.5kg / s变化至2kg / s。首先,使用有限元方法(FEM)开发和数学模型和数值模拟。对于计算模型的验证,从模拟结果计算壳侧平均露珠数(NU_S),并与可用的实验结果进行比较。比较研究表明,与传统的STHXSSB相比,STHXSHB具有每单位压力下降72-127%的传热系数,用于相同的壳侧质量流量。此外,STHXSHB比STHXSSB的壳侧压力下降59-63%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号