In September 26, 2012 NYPC Mailiao Ethylene Glycol (EG-4) plant reported a fire incident on the spool piece flanges of inlet pipeline of both two Ethylene Oxide (EO) reactors, R-1/R-2, which were founded 43 minutes later after Recycle Compressor tripped. 1. The deformed bolts were founded on the Inlet pipeline spool piece flanges of both R-1 and R-2 reactors, which were caused by unexpected extra high temperature, leaded to the leakage of ethylene mixed gas and spontaneous combustion. 2. The insufficient and invalidated emergency vent, following the Recycle Compressor trip, triggered the abnormal oxidation reaction of ethylene/oxygen mixed gas at the front-end of both two reactors, 180 seconds after compressor trip, which gave rise to the extra high temperature in the reactor inlet pipeline and reactor dome. 3. The 6 inches valve of emergency vent kept open 90 seconds following the compressor trip, but the pressure drop was only 1.5 Bar, less than safety criterion 3.0 Bar. It indicated an insufficient vent quantity and created a possible pocket of gas of explosive concentration. 4. Recycle Compressor was tripped by low oil pressure while its affiliate main and auxiliary oil pumps losing its 380V power supply at the same time. 5. The ACB(air circuit breaker) of 380V power panel, MCC-100/200, was tripped by ground fault relay protection resulted in stopping of power supply for all its distributed seventeen equipment, which included not only the main and auxiliary oil pumps of Recycle Compressor but also the air cooler fan motors of CO2 stripper condenser. 6. The stator winding damage of air cooler fan motor caused an unexpected trip of the upstream ACB of 380V power distribution panel for its improper setting of ground fault relay protection. Tripping the MCCB(molded case circuit breaker) of motor itself to be treated a satisfactory way for protection of power supply system.
机译:2012年9月26日,NYPC Mailiao乙二醇(EG-4)植物报告了在氧化乙烯(EO)反应器的入口管道的阀芯管道上的火灾,R-1 / R-2的型火焰植物均为43分钟后来回收压缩机绊倒后。 1.在r-1和R-2反应器的入口管线阀凸片上成立了变形的螺栓,这是由意外超高温引起的,导致乙烯混合气体和自发燃烧的泄漏。 2.在回收压缩机跳闸之后,紧急通风口不足,紧急通风口,在压缩机跳闸后180秒后引发乙烯/氧气混合气体的异常氧化反应,从而产生超高温在反应器入口管道和反应堆圆顶。 3.紧急通风口的6英寸阀门在压缩机跳闸后90秒打开,但压降仅为1.5巴,小于安全标准3.0巴。它表明了通风量不足,并产生了爆炸浓度气体的可能口袋。 4.回收压缩机通过低油压跳闸,而其联盟主要和辅助油泵同时失去其380V电源。 5. 380V电源板的ACB(空气断路器)MCC-100/200通过接地故障继电器保护跳闸,导致其所有分布式17个设备停止电源,这不仅包括主和辅助油泵Recycle压缩机还是CO2汽提示冷凝器的空气冷却器风扇电机。 6.空气冷却器风扇电机的定子绕组损坏引起了380V配电面板上游ACB的意外行程,以实现接地故障继电保护的不当设置。跳闸电机本身的MCCB(模压式壳体断路器)进行令人满意的供电系统保护方式。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号