首页> 外文会议>International Conference Interdisciplinarity in Engineering >Determining the Operating Diagram for the Cogeneration Steam Turbines
【24h】

Determining the Operating Diagram for the Cogeneration Steam Turbines

机译:确定热电联产汽轮机的操作图

获取原文

摘要

Participation in the electricity market of the combined heat and power plants requires the establishment of the net and gross power of the cogeneration restriction, which will be picked from the schedule offer of power producers, to introduce it with priority in the order of merit without restrictions. The paper presents the operational regimes for the extraction condensation steam turbines and the mathematical model for determining the operating diagram. It presents concrete case for the double extraction condensation turbine type DSL-50-1. This type of turbine is found in most the combined heat and power plants of Romania, which provides centralized heat supply of the big cities.
机译:参与综合发电和发电厂的电力市场需要建立热电联产限制的净和总权力,将从电力生产商的日程报价中挑选,以优先级为优先率,无需限制。本文介绍了提取冷凝蒸汽轮机的操作方案和用于确定操作图的数学模型。它为双提取冷凝涡轮机DSL-50-1提供了混凝土盒。这种类型的涡轮机在大多数罗马尼亚的综合热量和发电厂中找到,这为大城市提供集中供热。