摘要

Primary and secondary interleaving is normally used to minimize the leakage inductance and winding losses in high-frequency (HF) transformers used in high-power isolated dc-dc converters. Higher switching frequencies lead to the skin and proximity effects more significant, further more, the reduction of leakage inductance and the increase of winding losses. After analyzing the nonlinear distributions of the magnetic field strength and current density along the conductor thickness at high frequency, this paper presents a novel analytical calculation method considering the strong frequency dependence of transformer parameters, which is suitable for the non-interleaving, partially-interleaving, and fully-interleaving winding arrangements. A 4.5kHz, 5kVA HF transformer test model with amorphous core is built, and finite-element method (FEM) simulation and measurement are carried out to verify the method.
机译:通常和次级交织通常用于最小化高功率隔离DC-DC转换器中使用的高频(HF)变压器中的漏电电感和绕组损耗。更高的开关频率导致皮肤和接近效果更加显着,进一步更大,泄漏电感的降低和绕组损耗的增加。在高频下沿导体厚度分析磁场强度和电流密度的非线性分布后,考虑到变压器参数强频率依赖性的新型分析计算方法,适用于非交错,部分交织,完全交错的绕组布置。建立了4.5kHz,采用非晶芯的5kVA HF变压器测试模型,并进行了有限元方法(FEM)仿真和测量以验证该方法。