With energy shortage issue rises, value of energy conservation grows. The energy consumption of HVAC system reaches about 50% of the building especially for the hot and humid ambient condition in Taiwan. Energy modelling code eQUEST was applied to evaluate the energy consumption of a hotel building. Through the validation of simulation data and field measurement data, the energy-efficient chiller sizing approach can be obtained. The results revealed that the energy saving of 10.5% can be achieved by optimizing the chiller capacity sizing. The approach by energy modelling in this study will identify the best practice under limited budget as well as to reduce the trial-and-error effort while chiller sizing decision for energy saving have to be carried out.
机译:随着能源短缺问题上升,节能的价值增长了。 HVAC系统的能量消耗占该建筑的大约50%,特别是台湾的炎热和潮湿的环境条件。能源建模代码适用于评估酒店建筑的能源消耗。通过验证模拟数据和现场测量数据,可以获得节能冷却器尺寸方法。结果表明,通过优化冷却器容量尺寸,可以实现10.5%的节能。本研究中的能源建模的方法将确定有限预算下的最佳实践,并减少试验和错误努力,同时必须进行节约能源的冷却尺寸决定。