首页> 外文会议>IEEE Nuclear Science Symposium >SUV/Patlak-4D whole-body PET/CT dynamic and parametric imaging: clinical demonstration and validation of SUV synthesis from dynamic passes
【24h】

SUV/Patlak-4D whole-body PET/CT dynamic and parametric imaging: clinical demonstration and validation of SUV synthesis from dynamic passes

机译:SUV / Patlak-4D全身PET / CT动态和参数成像:动态通行证临床演示和SUV合成的验证

获取原文

摘要

Whole-body (WB) PET/CT imaging currently involves single-frame, i.e. static, PET acquisitions over a set of axial bed positions to form standardized uptake value (SUV) images. However, SUV is considered semi-quantitative due to its dependence on post-injection scan time and subject physiology. Recently, we introduced a class of novel WB dynamic PET/CT scan protocols capable of acquiring PET data over multiple time frames at each bed to enable quantitative WB parametric PET imaging. In this study, we are validating a special dynamic WB 18F-FDG PET/CT framework supporting synthesis of static-equivalent SUV as well as dynamic and parametric Patlak WB images from a single set of WB passes acquired within the standard-of-care post-injection time window of 18F-FDG PET/CT exams. The proposed protocol, streamlined for wide clinical adoption, consists of four unidirectional WB passes of constant bed frames (30 sec) or equivalent bed speeds, beginning 1h after injection. The acquired data at each bed may later be used by a direct 4D Patlak reconstruction algorithm to obtain parametric WB Ki images after utilizing a population-based model to infer the missing first 1h of the input function. Moreover, the same data can be added at each bed to synthesize static PET frames and equivalent SUV WB PET images. For the clinical evaluation of the proposed method, we consented patients scheduled for their regular WB 18F-FDG PET/CT exam to undergo afterwards a second PET-only scan, for the same total scan time, using our protocol. SUV mean comparisons at focal uptake ROIs between the step-and-shoot (S&S) static SUV and the respective synthetic SUV images yielded <14% and <20%.differences, primarily attributed to post-smoothing, when synthesis was conducted on S&S and continuous bed motion scan modes respectively. In addition, the direct 4D Patlak Ki WB images exhibited similar noise levels, while offering similar or better lesion contrast and enhanced quantification relative to SUV.
机译:全身(WB)PET / CT成像目前涉及单帧,即静态,PET在一组轴向床位置采集以形成标准化的摄取值(SUV)图像。然而,由于其对注射后扫描时间和主体生理学的依赖性,SUV被认为是半定量的。最近,我们介绍了一类新型WB动态PET / CT扫描协议,其能够在每张床上的多个时间框架上获取PET数据,以实现定量WB参数PET成像。在这项研究中,我们正在验证支持静态等效SUV的合成的特殊动态WB 18F-FDG PET / CT框架,以及来自在护理标准柱中获取的一组WB通行证的动态和参数Patlak WB图像 - 18F-FDG PET / CT考试的引发时间窗口。所提出的协议,精简临床采用,包括四个单向WB通过的恒定床框架(30秒)或等效床速度,从注射后开始1小时。在每个床上的所获取的数据可以在利用基于人群的模型以推断输入功能的前1H缺失之后获得参数WB ki图像。此外,可以在每张床上添加相同的数据,以合成静态宠物帧和等同的SUV WB PET图像。对于拟议方法的临床评估,我们同意患者预定其常规WB 18F-FDG PET / CT考试,然后使用我们的协议进行同一总扫描时间的第二次宠物扫描。 SUV平均比较阶梯和芽(S&S)静态SUV与各自合成的SUV图像之间的焦点摄取ROI的比较产生<14%和<20%。改性,主要归因于后平滑,当S&S和S&S连续床运动扫描模式。此外,直接4D Patlak Ki WB图像表现出类似的噪声水平,同时提供相似或更好的病变对比度和相对于SUV的增强量化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号