One of the usual measures to increase the energy efficiency in automotive vehicles has been the adoption of generators with variable voltage systems, commanded by the vehicle control unit. Thus, the vehicle system voltage no longer remains constant during operation of the engine, but becomes variable as needed to charge the vehicle electrical system and better use of available engine torque. A study using the Design for Six Sigma (DFSS) methodology was performed in order to understand the influence of the supply voltage and of the fuel conductivity in the lifetime of fuel pump commutation system by brushes. Durability tests were conducted in bench test, where parameters of temperature, current draw, voltage and fuel conductivity were monitored, correlating them with the results of wear in the pump commutation system. The conclusion of the study shows how the fuel pump life varies according to the supply voltage and the conductivity of the fuel used, given that the conductivity can be affected not only by the fuel composition, but also for its quality.
机译:提高汽车车辆能源效率的通常措施之一是采用具有可变电压系统的发电机,由车辆控制单元命令。因此,在发动机的操作期间,车辆系统电压不再保持恒定,而是根据需要变得可变,以对车辆电气系统充电以及更好地利用可用发动机扭矩。使用设计为六种Sigma(DFSS)方法的设计,以便通过刷子理解电源电压和燃料泵换向系统的寿命中的电源电压和燃料电导率的影响。耐久性测试在台凳测试中进行,其中监测温度,电流拉伸,电压和燃料电导率的参数,将它们与泵换向系统磨损的结果相关联。该研究的结论示出了燃料泵寿命如何根据所使用的燃料的电源电压和导电性而变化,因为不仅可以受燃料组合物影响,而且还可用于其质量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号