首页> 外文会议>International Conference on Solar Heating and Cooling for Buildings and Industry >Effect of receiver temperature on performance evaluation of silver coated selective surface compound parabolic reflector with top glass cover
【24h】

Effect of receiver temperature on performance evaluation of silver coated selective surface compound parabolic reflector with top glass cover

机译:接收器温度对顶玻璃盖的银涂层选择性表面复合抛物面的性能评价的影响

获取原文

摘要

The paper explores the experimental results of the prototype compound parabolic trough made of G.I and silver coated selective surface. The performance of collector has been evaluated with three kinds of receivers' coated with two kinds of receiver coatings black copper and black zinc and top cover. This line focusing parabolic trough yields instantaneous efficiency of 60% with top cover. A simple relationship between the parameters has been worked out with the regression analysis. Actual field experimentation for performance evaluation of prototype system has been done during month of April and May 2012 at Shivaji university, Kolhapur [Latitude: 16.42° N, Longitude: 74.13°W]
机译:本文探讨了由G.I和银涂层选择性表面制成的原型复合抛物面槽的实验结果。收集器的性能已经用三种接收器涂有两种接收器涂层黑色铜和黑色锌和顶盖进行了评估。该线聚焦抛物面槽的瞬时效率为60%,顶盖。参数之间的简单关系已经使用回归分析来解决。在4月份和2012年5月在夏波吉大学的月份进行了实际现场实验,在Shivaji University,Kolhapur [纬度:16.42°N,经度:74.13°W]