首页> 外文会议> >Misconnection squelching in all-optical ring networks
【24h】

Misconnection squelching in all-optical ring networks

机译:全光环网中的误连接静噪

获取原文
获取原文并翻译 | 示例

摘要

Misconnection means the condition in which traffic destined for a given node is incorrectly routed to another node and no corrective action has been taken when protection are executed in ring networks. In order to perform a ring switch, the protection channels are essentially shared among each span of the ring. Also, extra traffic may reside in the protection channels when the protection channels are not currently being used to restore working traffic transported on the working channels. Thus, each protection channel is subject to use by multiple services (services from the same wavelength but on different spans, and service from extra traffic). If adopting Multiplex Section (MS) shared protection in ring networks, with no extra traffic on the ring, under certain multiple spans failures, such as those that cause node(s) isolation, services (from the same wavelength but on different spans) may contend for access to the same protection channel. This yields a potential for misconnected traffic.
机译:错误连接是指在给定节点发送流量时将其错误地路由到另一个节点,并且在环网中执行保护时未采取纠正措施的情况。为了执行环网切换,保护通道基本上在环网的每个跨度之间共享。而且,当当前不使用保护信道来恢复在工作信道上传输的工作业务时,额外的业务可能驻留在保护信道中。因此,每个保护信道都受到多种服务的使用(来自相同波长但跨度不同的服务,以及来自额外流量的服务)。如果在环网中采用多路复用段(MS)共享保护,而环上没有额外的流量,则在某些多跨度故障(例如导致节点隔离的故障)下,服务(来自相同波长但跨度不同)可能会争用同一保护通道。这可能会导致流量错误连接。