首页> 外文会议>Congres International du Froid de I'IIF >EXPERIMENTAL STUDY OF R290 ENHANCED SYSTEM PERFORMANCE IN RESIDENTIAL AIR-CONDITIONERS AND HEAT PUMPS
【24h】

EXPERIMENTAL STUDY OF R290 ENHANCED SYSTEM PERFORMANCE IN RESIDENTIAL AIR-CONDITIONERS AND HEAT PUMPS

机译:R290增强居民空调和热泵系统性能的实验研究

获取原文

摘要

R290 is one of the alternative fluids for replacing R22, because of low GWP and similar thermodynamic performance. In this study, drop-in performance of R290 and enhanced performance of R290 with suction line heat exchanger (SLHX) are measured in residential air-conditioners and heat pumps. The experiment is conducted in a heat pump test bench and the air conditioner was initially designed for R22 and altered by adding a SLHX. The test showed that with slight alteration, SLHX improved the cooling capacity and COP of R290 in the cooling mode, and slightly increased heating capacity with no obvious change of COP in heat pump condition. Since the pressure drop along the suction line, about 36 KPa, is acceptable and the heat transfer rate of the SLHX, about 125W, is relatively low, the performance of SLHX with higher heat transfer rate is forecasted with thermodynamic analysis.
机译:R290是用于更换R22的替代流体之一,由于低GWP和类似的热力学性能。在该研究中,在居民空调和热泵中测量R290的掉落性能和R290的增强性能,采用吸入管线热交换器(SLHX)。实验在热泵测试台中进行,最初设计用于R22的空调,并通过添加SLHX来改变。该试验表明,随着略微改变,SLHX在冷却模式下提高了R290的冷却能力和COP,并略微增加了热泵条件下的COP变化。由于沿着吸入管线的压降,约36kPa是可接受的并且SLHX的传热速率约为125W,相对较低,因此热力学分析预测具有较高传热速率的SLHX的性能。