首页> 外文会议>Congres International du Froid de I'IIF >PERFORMANCE IMPROVISATION OF WINDOW AIR-CONDITIONER EMPLOYING INDIRECT EVAPORATIVE COOLING
【24h】

PERFORMANCE IMPROVISATION OF WINDOW AIR-CONDITIONER EMPLOYING INDIRECT EVAPORATIVE COOLING

机译:橱窗空调的性能即兴采用间接蒸发冷却

获取原文

摘要

A phenomenal growth is observed in refrigeration and air-conditioning industry over the last decade. In this context it has been essential and desirable to operate the system at higher energy efficiency level. Energy efficiency of a refrigeration air-conditioning system is greatly influenced by its condenser pressure. A novel system is developed to improve the window air conditioner system performance incorporating indirect evaporative cooling where evaporator condensate is utilised to enhance the condenser cooling. Experiments were carried out under various operating conditions and system performance was measured. It is observed that cooling capacity is increased by 2.6% and power consumption reduced by 12.1% as a result coefficient of performance enhanced by 14.8%.
机译:在过去十年中,在制冷和空调行业中观察到了现象的生长。在这种情况下,在更高的能效水平下操作系统是必要的并且是必要的。制冷空调系统的能量效率受其冷凝器压力的影响。开发了一种新颖的系统,以改善窗户空调系统性能,包括间接蒸发冷却,其中利用蒸发器冷凝物来增强冷凝器冷却。在各种操作条件下进行实验,并测量系统性能。观察到,冷却能力增加2.6%,功耗降低12.1%,结果性能系数增强14.8%。