This paper examines cracks which occurred at the re-entrant corners at the dapped ends of bulb tee girders used on the MIA Mover APM System at Miami International Airport. Cracks were initially identified during load testing at the precast yard, although typically they did not occur until the beams were erected. The load test and crack mechanism is described herein. Post-erection cracking is compared with that observed under load test conditions and differences are discussed. FDOT criteria were applied in determining the appropriate protection strategy.
机译:本文研究了在迈阿密国际机场的MIA MOVER APM系统的灯泡TEE梁的抛射末端处于再参赛者角落发生的裂缝。 最初在预制码处的负载测试期间最初识别裂缝,但通常它们不会发生,直到纱线被竖立。 本文描述了负载测试和裂纹机制。 与在载荷试验条件下观察到的勃起后开裂和差异进行比较。 在确定适当的保护策略时应用了电器标准。