For the development of small microbolometer for mobile applications, new pixel design to enhance fill factor by sharedanchor structures is suggested and it can be possible to make a one anchor per unit pixel. Fill factor increases 10% more than that of normal unshared-anchor design. Amorphous-silicon based microbolometer has been fabricated with 64x64 arrays of 25um pixel size to verify proposed design. Mechanical flatness of shared-anchor structure is enhanced. Responsivity is enhanced from 1.08e+5 V/W to 1.23e+5 V/W due to the increase of fill-factor compared to unsharedanchor. There are no mechanical, electrical and thermal crosstalk problems with adjacent pixels.
机译:对于移动应用的小型微生物仪的开发,建议了新的像素设计来增强Sharedanchor结构的填充因子,并且可以每单位像素制作一个锚。填充因子比正常的未分流锚设计的增加10%。基于非晶硅微生物仪采用64x64阵列的25um像素尺寸制造,以验证提出的设计。共用锚固结构的机械平坦度得到增强。由于填充因子的增加,与未实施中的填充因子的增加,响应性从1.08e + 5v / w增加到1.23e + 5 v / w。没有与相邻像素的机械,电气和热串扰问题。