首页> 外文会议>International High Performance Building Conference at Purdue >Deep Retrofit System Solution Assessment for Philadelphia Navy Yard Office Buildings
【24h】

Deep Retrofit System Solution Assessment for Philadelphia Navy Yard Office Buildings

机译:Philadelphia海军院子办公楼深度改造系统解决方案评估

获取原文

摘要

Initial assessments of economically attractive integrated building energy system solutions that can substantially reduce energy consumption in two medium-sized office buildings in the Philadelphia Navy Yard are presented. These sites were selected because they are the current and future headquarters of the DOE Energy Efficient Buildings Hub (EEB HUB). Energy efficient retrofit solutions involving integrated building systems with 40-60% site- and source-energy reduction potential relative to selected baseline energy consumption configurations are identified. The scope of retrofit options explored and integrated involve the building envelope, lighting and HVAC systems as well as the related control systems, providing a spectrum of retrofit options that range from low-/no-cost options to relatively higher capital cost options that involve significant capital upgrades and facility renovations. The energy savings estimates are based on combining multiple energy conservation measures (ECMs) that are tailored to the building use type and climate conditions. Energy performance (energy savings potential) and economic impact (NPV, IRR, and simple payback) of these retrofit system solution recommendations are assessed for two office buildings - Building 101 and Building 661, at the Philadelphia Navy Yard. A suite of retrofit system packages is presented for each building with a range of initial investments and economic returns to assist the investment decision making process, by stakeholders such as the building owner and operator. Results of the cost benefit analyses will be presented in light of incentives for high performance office buildings in the Philadelphia ten-county region.
机译:初步评估经济上有吸引力的综合建筑能源系统解决方案,可以提出了在费城海军围场的两个中型办公楼中大大降低了能源消耗。这些网站被选中,因为它们是DOE节能建筑中心(EEB HUB)的当前和未来总部。鉴定了涉及具有40-60%的集成建筑系统的能量有效改造解决方案,具有相对于所选基线能耗配置的40-60%的站点和源能量降低电位。探索和集成的改造选项的范围涉及建筑信封,照明和HVAC系统以及相关控制系统,提供从低/无成本选项到相对更高的资本成本选项的范围的转换选项的光谱资本升级和设施装修。节能估计是基于组合用于建筑物使用类型和气候条件的多种节能措施(ECM)。这些改造系统解决方案建议的能源绩效(节能潜力)和经济影响(NPV,IRR和简单的回报)被评估为两个办公楼 - 建筑物101和361年,在费城海军院子里。为每栋建筑提供一系列改装系统套餐,提供一系列初始投资和经济回报,以协助投资决策过程,由建筑物业主和运营商等利益相关者。成本效益分析的结果将借鉴费城十县地区的高性能办公楼的激励措施。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号