首页> 外文会议>International Conference on Micro Electro Mechanical Systems >A MICROFLUIDIC SYSTEM INTEGRATED WITH OPTICAL DETECTION DEVICES FOR AUTOMATIC DETECTION OF C-REACTIVE PROTEIN
【24h】

A MICROFLUIDIC SYSTEM INTEGRATED WITH OPTICAL DETECTION DEVICES FOR AUTOMATIC DETECTION OF C-REACTIVE PROTEIN

机译:一种与光学检测装置集成的微流体系统,用于自动检测C反应蛋白

获取原文

摘要

C-reactive protein (CRP) is commonly known as a clinical marker, which has been identified as an independent predictor for cardiovascular diseases such as heart attack and stroke. In this study, a new microfluidic system for automatic measurement of CRP is reported. The entire process including sample pre-treatment, incubation between target CRP and anti-CRP antibody, developing process and detection can be automatically performed on a single chip. In addition, chemiluminescent signal was measured by using a home-made luminometer to quantify the concentration of CRP. When compared to previous works, not only can the new chip perform the entire process by integrating a new micro-injector, but a new CRP-specific DNA aptamer was also used for CRP measurement. Experimental data showed that the developed system can automate the entire process within 30 minutes with a detection limit of 0.0125 mgL~(-1), which was superior to previous works.
机译:C-反应蛋白(CRP)通常称为临床标记物,其已被鉴定为心血管疾病如心脏病和中风的独立预测因子。在该研究中,报道了一种用于自动测量CRP的新型微流体系统。在单个芯片上可以自动在单个芯片中自动执行靶CRP和抗CRP抗体之间的培养,在靶CRP和抗CRP抗体之间进行培养,包括样品预处理的整个方法。另外,通过使用自制发光计来量化CRP浓度来测量化学发光信号。与以前的作品相比,新芯片不仅可以通过整合新的微型注射器来执行整个过程,而是新的CRP特异性DNA适体也用于CRP测量。实验数据表明,发达的系统可以在30分钟内自动化整个过程,检测限为0.0125 MgL〜(-1),其优于以前的作品。