High strength conductors, used for the construction of pulsed magnets at NHMFL, must withstand demanding stress, strain and cyclic fatigue requirements. The safe design and operation of pulse magnets requires an understanding of the expected conductor performance as determined from design-specific low-cycle fatigue tests. A test fixture has been developed to perform fatigue stress cycling at 77 K that enables the application of axial tension and compression in a stress or strain control mode. Special wedge grips with low thermal mass were designed that are capable of reverse cycling (tension-compression) of various size specimens. The low cycle fatigue life of Glidcop-AL60TM, a commercially available high strength/high conductivity conductor, has been characterized and is reported. Stress and strain data acquired for the tests, are evaluated to assess the material's strain hardening or strain softening characteristics and its influence on fatigue life. The influence of test control mode (stress control versus strain control), and r-ratio on the fatigue life, are discussed.
机译:高强度导体,用于在NHMFL施工脉冲磁铁的强度导体,必须承受要求苛刻的应力,应变和循环疲劳要求。脉冲磁铁的安全设计和操作需要了解从设计特定的低周期疲劳测试中确定的预期导体性能。已经开发了一种测试夹具以在77K处执行疲劳应力循环,其能够在应力或应变控制模式下施加轴向张力和压缩。设计具有低热质量的特殊楔形夹具,其能够反向循环(张力压缩)的各种尺寸样本。据报道,Glidcop-Al60tm的低循环疲劳寿命已经表征并据报道了可商购的高强度/高导电导体。评价用于测试的应力和应变数据,以评估材料的应变硬化或菌株软化特性及其对疲劳寿命的影响。讨论了测试控制模式(应力控制与应变控制)和R比上的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号