A cryogenic test rig was designed and fabricated to measure the heat leak from room temperature to 2 K for the Accelerator production of Tritium (APT) 700 MHz, 210 kW continuous wave (CW) co-axial power coupler (PC). The outer conductor of the PC is stainless steel with 15 μm copper film on the inside. The copper inner conductor operates at room temperature and contributes considerable infra-red radiation heat load to 2 K. Two thermal intercept heat exchangers cooled by supercritical helium are incorporated into the outer conductor to reduce the heat conducted to the lowest temperatures. A brief description of the experimental apparatus is presented. A comparison of the experimental measurements and the predictions of a detailed thermal model is given. There is also a discussion of anomalous behavior observed in the thermal intercepts, and fluctuations in the helium coolant properties.
机译:设计和制造了低温试验台,以测量从室温到2K的热泄漏,以便加速器生产氚(APT)700 MHz,210 kW连续波(CW)共轴电耦合器(PC)。 PC的外导体是不锈钢,内部有15μm铜膜。铜内导体在室温下运行,并将相当大的红外线辐射热负荷贡献到2k。通过超临界氦冷却的两个热拦截热交换器结合到外导体中,以将传导的热量降低到最低温度。提出了实验装置的简要描述。给出了实验测量和详细热模型的预测的比较。还存在在热截距中观察到的异常行为,并在氦气冷却剂性质中波动。