首页> 外文会议>International Conference on Remediation of Chlorinated adn Recalcitrant Compounds >Thermal Treatment of Eight CVOC Source Areas to Near-Nondetect Concentrations
【24h】

Thermal Treatment of Eight CVOC Source Areas to Near-Nondetect Concentrations

机译:八个CVOC源区的热处理到近非禁止浓度

获取原文

摘要

This presentation describes a unique thermal application used at Dunn Field at the former Memphis Depot in Tennessee. The removal of eight high-concentration source zones by simultaneous thermal treatment was accomplished in 6 months – using one thermal system to cover all eight areas. Unit costs for applying in situ thermal desorption (ISTD) were below $80 per cubic yard treated. The removal of the source areas will facilitate transfer and reuse of the property under the Base Realignment and Closure (BRAC) Program. The eight separate source zones contained chlorinated volatile organic compounds (CVOCs) in a tight loess (silt/clay) above the water table. Primary contaminants were PCE, TCE, and 1,1,2,2-Tetrachloroethane. The source areas were as much as 1,200 ft apart. A target volume of 49,950 cubic yards of subsurface material to a depth of 30 ft was treated in a period of 177 days.
机译:本演示文稿描述了在田纳西州前孟菲斯仓库的Dunn田地使用的独特热应用。通过同时热处理去除八个高浓度源区 - 使用一个热系统在6个月内完成,以覆盖所有八个区域。用于原位热解吸(ISTD)的单位成本低于每立方围场治疗的80美元。源区的去除将促进基本调整和关闭(BRAC)计划下的财产的转移和重用。八个单独的源区含有氯化挥发性有机化合物(CVOC)在水位上方的紧身黄土(淤泥/粘土)中。初级污染物是PCE,TCE和1,1,2,2-四氯乙烷。源区分开多达1,200英尺。在177天的时间内处理49,950立方码的地下材料的49,950立方码的地下材料的体积。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有