The discovery of chlorinated volatile organic compounds (CVOCs) in the aquifer underlying a manufacturing facility prompted the initiation of an aggressive vol- untary site wide cleanup. Earth Tech, Inc. was selected to develop, design, construct, and operate a site-wide remedial strategy. Project challenges included multiple potential source locations in the unsaturated zone, the complexity of the groundwater flow regime, depth and concentrations of the CVOCs as high as 10,000 ppb, and working within an active third party manufacturing facility. Given a large number of potential source areas within the plant, delineation of CVOC impacts to the unsaturated zone was performed by the installation of an innovative soil vapor extraction system, rather than performing ex- tensive soil sampling within the operating manufacturing facility. In conjunction with the unsaturated zone treatment a comprehensive groundwater remediation system was de- signed and installed to provide plume capture under the most extreme groundwater flow conditions. In addition to the on-site remedial actions, off-site plume delineation was per- formed using direct push membrane interface probe (MIP) technology. Since installation, the site wide program has removed over 900 pounds of CVOCs from the unsaturated zone minimizing future impacts to the groundwater. In addition, the groundwater remediation system has removed or dechlorinated over 1500 pounds of CVOCs from the on-site groundwater, while preventing further off-site migration, all with minimal inter- ference to facility production. The site investigations conducted adjacent to the manu- facturing facility has identified several other off-site sources that have commingled in portions of the plume both up gradient and down gradient of the facility.
机译:在制造工厂的含水层中发现氯化挥发性有机化合物(CVOC)促使发起激进的体育场地宽清理。 Earth Tech,Inc。被选为开发,设计,构建和运营网站范围的补救策略。项目挑战包括不饱和区中的多个潜在源位置,地下水流量的复杂性,CVOC的深度和浓度高达10,000 ppb,并在积极的第三方制造设施内工作。鉴于植物内的大量潜在源区域,通过安装创新的土壤蒸汽提取系统,对不饱和区进行CVOC冲击,而不是在运营制造设施内执行公平的土壤采样。结合不饱和区处理,定签署并安装综合地下水修复系统,以便在最极端地下水流动条件下提供羽流捕获。除了现场的补救措施外,使用直推膜界面探头(MIP)技术而采用非现场羽流划分。自安装以来,网站广泛的程序已经从不饱和区中取出超过900磅的CVOC,从而最大限度地减少了对地下水的影响。此外,地下水修复系统已从现场地下水中除去或脱氯,同时防止进一步的偏离现场迁移,所有内部均匀地迁移到设施生产。与制造工具相邻的网站调查已经确定了几种其他非现场来源,这些源在羽流的部分渐变和下降梯度的部分中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号