首页> 外文会议>Annual Conference of the Canadian Nuclear Society >Long-Term Performance Of The CANDU-Type Of Vanadium Self-Powered Neutron Detectors In NRU
【24h】

Long-Term Performance Of The CANDU-Type Of Vanadium Self-Powered Neutron Detectors In NRU

机译:NRU蜡烛型钒型自动中子探测器的长期性能

获取原文

摘要

The CANDU~(~R)-type of in-core vanadium self-powered neutron flux detectors have been installed in NRU to monitor the axial neutron flux distributions adjacent to the loop fuel test sites since 1996. This paper describes how the thermal neutron fluxes were measured at two monitoring sites, and presents a method of correcting the vanadium burn-up effect, which can be up to 2 to 3percent per year, depending on the detector locations in the reactor. It also presents the results of measurements from neutron flux detectors that have operated for over eight-years in NRU. There is good agreement between the measured and simulated neutron fluxes, to within +- 6.5percent, and the long-term performance of the CANDU-type of vanadium neutron flux detectors in NRU is satisfactory.
机译:核心钒自动中子磁通探测器的Candu〜(〜r)型已经安装在NRU中,以监测自1996年以来的环路燃料试验站附近的轴向中子磁通量分布。本文介绍了热中子通量的方式在两个监测位点测量,并提出了一种校正钒烧伤效果的方法,每年可以达到2至3次,这取决于反应器中的检测器位置。它还介绍了中子磁通检测器的测量结果,这些磁通检测器在NRU中运行超过八年。测量和模拟中子丝量之间存在良好的一致性,进入+ - 6.5内,NRU中的钒中子通量探测器的长期性能令人满意。