首页> 外文会议>IEEE Particle Accelerator Conference >BEAM DIAGNOSTICS FOR THE J-PARC MAIN RING SYNCHROTRON
【24h】

BEAM DIAGNOSTICS FOR THE J-PARC MAIN RING SYNCHROTRON

机译:J-Parc主环同步rotron的光束诊断

获取原文
获取外文期刊封面目录资料

摘要

Beam diagnostics: beam intensity monitors (DCCT, SCT, FCT, WCM), beam position monitors (ESM), beam loss monitors (proportional chamber, air ion chamber), beam profile monitors (secondary electron emission, gassheet) have been designed, tested, and will be installed for the Main Ring synchrotron (MR) of J-PARC (Japan Proton Accelerator Research Complex). This paper covers the basic design principle and specification of each monitor of the MR and the beam transport line from 3 GeV rapid cycling synchrotron to the MR (3-50BT), with a stress on how to cope with high power beam (average circulation current of ~13 A) and low beam loss operation (less than 0.5 W/m except a collimator, injection and extraction region). Some results of preliminary performance test using present beams and a radiation source will be reported.
机译:光束诊断:光束强度监测器(DCCT,SCT,FCT,WCM),光束位置监视器(ESM),光束损耗监视器(比例室,空气离子室),已经设计,测试,测试了梁轮廓监视器(二次电子发射,Gassheet) ,并将安装在J-PARC(日本质子加速器研究复杂)的主环同步rotron(MR)。本文涵盖了从3个GEV快速循环同步向MR(3-50BT)的MR和光束运输线的每个监视器的基本设计原理和规范,并强调如何应对高功率束(平均循环电流〜13 a)和低光束损耗操作(除准直器外,小于0.5 w / m,除了准直器,注射和提取区域)。报告使用当前梁和辐射源的一些初步性能测试的结果。