Pump Performance Tests as a Method of Determining Influent Mass Flows to Dairy Farm Anaerobic Digesters

机译:泵性能测试作为确定流入物质流入乳制品厌氧消化器的方法

获取原文

摘要

A new on-farm anaerobic digester (AD) monitoring protocol, recently released by the Association of State Energy Research Technology and Transfer Institutions (ASERTTI) is being used to assess seven anaerobic digesters on dairy farms in New York State.A key component of the ASERTTI protocol is to perform a mass balance of the AD system. Mass balance data is needed to determine system performance values such as: degree of manure stabilization, biogas produced per unit of influent, and subsequent electrical power produced per unit of influent. The optimal location in the system to obtain AD influent mass flow data is at the AD influent pump. However, pumps used to pump manure generally lack performance data, making it difficult to quantify mass flow without knowing the performance characteristics of the influent pump. In order to determine in-place pump performance, field tests were conducted on each of the two types of influent pumps used on the farms: centrifugal pumps and hydraulic piston pumps. The performance test for the hydraulic piston pump consisted of pumping AD influent to a separate vessel while counting the number of pump strokes; the wet weight per stroke was then determined. The pump test for the centrifugal pump consisted of fillingthe AD influent pit and then pumping the contents to the AD while measuring the change in depth of the pit every ten minutes throughout the test to determine the average flow rate for the dynamic pump head. To date, pump calibration tests have been performed on five of the seven farms. Volumetric efficiencies for four of the hydraulic piston pumps were found to be on average 91, 64, 83 and 57 percent based on three separate trials at each farm, pumping on average about 5,000 gallons per trial. Manure density tests performed the day of the pump performance evaluation resulted in specific gravities of 1.02, 1.01, 1.02 and 1.02, with respect to the efficiencies listed above. Average flow rates for two centrifugal pumps tested at one farm were found to be381 gpm and 564 gpm.
机译:最近由国家能源研究技术和转让机构(Asertti)协会发布的新农场厌氧挖掘机(AD)监测议定书,用于评估纽约州奶牛场的七位厌氧饮料。 Asertti协议是执行广告系统的质量平衡。需要质量平衡数据来确定系统性能值,例如:粪便稳定程度,每单位流入的沼气,以及每单位流入的电力产生的电力。系统中获得AD进水质量流量数据的最佳位置处于AD进水泵。然而,用于泵粪的泵通常缺乏性能数据,使得难以在不知道进水泵的性能特性的情况下量化质量流量。为了确定就地泵的性能,在农场使用的两种流动泵中进行现场测试:离心泵和液压活塞泵。液压活塞泵的性能试验包括泵送到单独的船只的泵浦,同时计算泵冲程的数量;然后测定每次中风的湿重。离心泵的泵测试包括填充到广告的坑,然后在整个测试中每10分钟测量坑深度变化的同时将内容物泵送到广告中,以确定动态泵头的平均流量。迄今为止,已在七个农场中的五个农场进行了泵校准测试。在每个农场的三项单独试验中,发现四个液压活塞泵的体积效率平均为91,64,83和57%,平均每次试验泵送约5,000加仑。粪便密度测试进行泵性能评估的日子导致1.02,1.01,1.02和1.02的比重,相对于上述效率。发现在一个农场测试的两个离心泵的平均流速被发现为381GPm和564普克。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号