Measurements during the last eight years show an increasing level of P{sub}(It), an indicator used for the flicker level. Furthermore, almost 50% of all technical customer complaints are flicker problems. The short-circuit power on the connection point is a very important parameter for controlling the fast voltage variations that lead to flicker. However, a high short circuit level can not be established unless investments in the low voltage grid are made. Analyzing the database of customers complaints shows that in only 25% of all cases the short-circuit power is less than the minimum value given in the national grid code, as indication. So other solutions, without investment in the network, are needed.
机译:在过去八年期间的测量显示了P {Sub}(IT)的增加,该指示器用于闪烁级别。此外,近50%的技术客户投诉都是闪烁的问题。连接点上的短路电源是用于控制导致闪烁的快电压变化的非常重要的参数。然而,除非进行低电压网格的投资,否则无法建立高短路电平。分析客户的数据库投诉显示,只有25%的所有情况,短路功率小于国家网格代码中给出的最小值,作为迹象。所以需要其他解决方案,没有网络投资。