摘要

Space Shuttle Columbia's catastrophic failure, the separation of a piece of spray-on-foam insulation (SOFI) from the external tank (ET) in the Space Shuttle Discovery's flight in 2005 and crack detected in its ET foam prior to its successful launch in 2006 emphasize the need for effective nondestructive methods for inspecting the shuttle ET SOFI. Millimeter wave nondestructive testing methods have been considered as potential and effective inspection tools for evaluating the integrity of the SOFI. This paper presents recent results of an investigation for the purpose of detecting vertical cracks in SOFI panels using a focused millimeter wave (150 GHz) reflectometer. The presented images of the SOFI panels show the capability of this reflectometer for detecting tight vertical cracks (also as a function of crack opening dimension) in exposed SOFI panels and while covered by a piece of SOFI ramp simulating a more realistic and challenging situation.
机译:航天飞机哥伦比亚的灾难性故障,从外部坦克(ET)的喷雾泡沫绝缘(SOFI)分离在2005年的Shovel Shorttle Discovery的航班中,在2006年成功推出之前在其ET泡沫中检测到的裂缝强调需要有效的非破坏性方法检查梭I et SOFI。毫米波无损检测方法被认为是评估SOFI完整性的潜在和有效的检查工具。本文介绍了用于使用聚焦毫米波(150GHz)反射计检测SOFI面板中的垂直裂缝的研究结果。 SOFI面板的所呈现的图像显示该反射仪的能力,用于检测暴露的SOFI面板中的垂直裂缝(也是裂缝开口尺寸)的垂直裂缝(也是裂缝开口尺寸的函数),同时由一块SOFI斜坡覆盖,模拟更加真实和具有挑战性的情况。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号