首页> 外文会议>Symposium on Quantitative Nondestructive Evaluation >Characterization of an Ultrasonic Transducer in a Pulse-Echo Setup
【24h】

Characterization of an Ultrasonic Transducer in a Pulse-Echo Setup

机译:脉冲回波设置中超声换能器的特征

获取原文

摘要

The effect that a transducer has on an ultrasonic measurement system can be completely characterized in terms of its input electrical impedance and sensitivity. Here, a simple model-based approach is described to determine both of these transducer parameters in a pulse-echo setup. It is demonstrated that it is important to compensate for cabling effects in the determination of these transducer parameters. The transducer sensitivity obtained using this new approach is compared to the sensitivity found using a more complex three-transducer method originally developed for lower-frequency acoustic transducers.. Also, the influence of the pulser/receiver settings on the measurements of the transducer impedance and sensitivity is discussed.
机译:换能器对超声测量系统的影响可以完全表征其输入电阻和灵敏度。这里,描述了一种简单的基于模型的方法来确定脉冲回波设置中的这些换能器参数。结果证明,在确定这些换能器参数时补偿布线效应是重要的。使用这种新方法获得的换能器灵敏度与使用最初为较低频率的声学传感器开发的更复杂的三传感器方法找到的灵敏度进行比较。此外,脉冲/接收器设置对换能器阻抗测量的影响讨论了敏感性。