An assessment of the extent of vibration transmission, attributable to non-structural partitions, was made using experimental tests and numerical simulations, for a recently constructed multi-storey reinforced concrete building. Mechanical excitation was provided to one floor. The extent of vibration on the floor above was found to be as high as 65 % of that recorded on the excited floor. A numerical model was also used to simulate the response to a person walking along a corridor. The extent of transmission was 9 % with partitions and 1.8 % without them. These findings imply that the vibration level on any given floor level will be due to excitation on that particular floor and also the not insignificant level of vibration that may be transmitted through structural and non-structural components due to concurrent activity from floors above and below. This issue of vibration transmission between floor levels is not addressed in any current guidance of floor vibration serviceability assessment and requires further detailed investigation.
机译:使用实验试验和数值模拟,对最近建造的多层钢筋混凝土建筑进行了非结构分区,对非结构分区的振动传输程度的评估。机械激发提供到一层。发现上面的地板上的振动程度高达65%在兴奋的地板上记录。数值模型也用于模拟沿着走廊行走的人的响应。透射程度为9%,分区为1.8%,没有它们。这些发现意味着任何给定楼层的振动水平将是由于在该特定地板上的激励,并且由于从上方和下方的楼层的并发活性,可以通过结构和非结构部件传输的不是微不足道的振动水平。在地板振动可维护性评估的任何当前指导下都没有解决楼层水平之间的振动传输问题,并需要进一步详细的调查。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号