Beta spectrometry with metallic magnetic calorimeters

机译:具有金属磁性量热计的β光谱法

获取原文

摘要

Metallic magnetic calorimeters are a specific type of cryogenic detectors that have been shown to enable precise measurement of the shape of low energy beta spectra. The aim of their use at LNHB is the determination of the shape factors of beta spectra. The beta source is enclosed in the detector absorber, allowing for very high detection efficiency. It has turned out that the type of source is of crucial importance for the correctness of the measured spectrum. Spectra of ~(63)Ni measured with several sources prepared by drying a NiCl_2 solution differ from one another and from theory, whereas spectra measured with electroplated sources are reproducible and agree with theory. With these latter measurements we could confirm the atomic exchange effect down to very low energy (200 eV).
机译:金属磁热量计是一种特定类型的低温检测器,已被证明能够精确测量低能量β光谱的形状。它们在LNHB时使用的目的是测定β光谱的形状因子。 β源封闭在检测器吸收器中,允许非常高的检测效率。事实证明,对测量光谱的正确性至关重要的来源是至关重要的。用通过干燥NiCl_2溶液制备的几种来源测量的〜(63)的光谱与彼此不同,并且由理论不同,而用电镀来源测量的光谱是可再现的,并且与理论相提并论。随着后一种测量,我们可以确认原子交换效应下降到非常低的能量(200eV)。