摘要

The centrifugal compressor of CKD Energo driven by the Ukrainian gas turbine GT 3000 works for the underground storage of natural gas in northern Moravia near town Stramberk. The paper presents the results of experimental investigations of surge limits and anti-surge control function at three typical levels of the compressor speeds. The position of stability points on characteristics is significantly influenced by reference Mach number. This conclusion is not considered in anti-surge control (ASC) setting. Setting conditions were suitable for high rotor speeds. On the basis of the obtained experimental data it can be concluded, that the working area of the gas storage compressor can remarkably be extended at low rotor speeds by correction of the ASC activation.
机译:CKD Energo的离心式压缩机由乌克兰燃气轮机GT 3000为地下储存天然气的地下储存,摩拉维亚州北部斯特拉曼克镇。 本文提出了在三种典型水平的压缩机速度下的浪涌限制和抗喘振控制功能的实验研究结果。 稳定性点对特性的位置受到参考马赫数的显着影响。 该结论不考虑在抗喘振控制(ASC)设置中。 设定条件适用于高转子速度。 基于所获得的实验数据,可以得出结论,通过校正ASC激活,气体储存压缩机的工作区域可以在低转子速度下显着延伸。