首页> 外文会议>World Conference on Timber Engineering >Evaluation of seismic performance of timber structures with shear walls by pseudo-dynamic tests
【24h】

Evaluation of seismic performance of timber structures with shear walls by pseudo-dynamic tests

机译:伪动动力学测试评估剪力墙木结构的地震性能

获取原文

摘要

Pseudo-dynamic tests were conducted on two-story timber structures with plywood-sheathed shear walls with opening of different configuration, and the effects of the racking strength of the first and second stories to the seismic response of the structures were studied. The specimens had 3-by 3m in width and depth and 6m in height. It had 3-by 3m plywood-sheathed shear walls with an opening with different configuration. Test results were compared with those of the individual shear walls that consist of the first story of the specimen. It was found that the pseudo-dynamic test of a single shear wall element with the mass supported by that shear wall (added that of the upper story) is appropriate to estimate the seismic performance of shear walls. The test results were also compared with the simulation by time-history earthquake response analysis, and they showed good agreement with the test results.
机译:在具有不同构造的开口的胶合板护套剪力墙的两层木结构上进行了伪动力测试,研究了第一和第二故事的架子强度对结构的地震反应的影响。试样的宽度和深度为3米,高度为6米。它具有3乘3米的胶合板 - 护套剪力墙,具有不同的配置开口。将测试结果与由由标本的第一个故事组成的各个剪切墙进行比较。结果发现,单剪切壁元件的伪动态试验具有由该剪切壁支撑的质量(增加了上层的)是适当的,以估计剪切壁的地震性能。测试结果也与历史地震响应分析的模拟相比,它们与测试结果表现出良好的一致性。