摘要

The calibration of optical CT scanners often involves referencing of transmission values to surrounding refractive index matching liquid. Often these liquids suffer from wavelength dependencies or can degrade during the course of a scan. In this paper, we describe a black liquid that serves as a stable reference for attenuation measurements. An optically stable, refractive index matching liquid for optical CT scanning of hydrogels was developed. The solution contains: water, glycerol, surfactant and carbon black. Sequential transmission measurements demonstrated less than 5percent variation in transmission during a two week storage period at room temperature. Black solutions are expected to minimize spectral beam hardening artefacts associated with polychromatic light sources.
机译:光学CT扫描仪的校准通常涉及引用传输值与周围的折射率匹配液体。这些液体通常遭受波长依赖性,或者在扫描过程中会降低。在本文中,我们描述了一种用于衰减测量的稳定参考的黑色液体。开发了用于水凝胶的光学CT扫描的光学稳定的折射率匹配液体。溶液含有:水,甘油,表面活性剂和炭黑。顺序传输测量值在室温下的两周储存周期期间透明的变速数小于5。预计黑色溶液将最小化与多色光源相关的光谱束硬化伪影。